General Building Lighting
Fixtures that illuminate corridors, stairs, restrooms, and work areas so the building can be occupied are listed structural components under Treas. Reg. §1.48-1(e)(2). Changing lamp type does not, by itself, change the class. Decorative exceptions are fact-specific and are discussed on the specialty-lighting page. Educational information, not tax advice.
Educational information, not tax advice.
Updated 2026-10-14
Key takeaways
- The regulation lists lighting fixtures among structural components relating to operation or maintenance of a building.
- The residential rental matrix treats ceiling fans that are the typical primary light source as building property.
- Metro National treated false ceilings with lay-in lighting as structural components on those office and medical facts.
- Building-mounted exterior occupancy lighting is treated as building in the matrices; pole-mounted site lighting is often discussed as a land improvement.
- Do not reclass house lighting because decorative lighting nearby was allowed in another case.
Corridor, stair, restroom, parking-garage, and open-office lighting make a building usable. Treas. Reg. §1.48-1(e)(2) captures that function by listing lighting fixtures among structural components, together with electric wiring, plumbing, central heating and air conditioning, partitions, floors, ceilings, sprinkler systems, and fire escapes. Tangible personal property under section 1.48-1(c) excludes those structural components. A building under section 1.48-1(e)(1) is a structure enclosing space, usually roofed, used for shelter, housing, or working, office, parking, display, or sales space — including garages.
Hospital Corp. of America held that these investment-credit definitions still apply under MACRS. The IRS acquiesced in that legal conclusion, not in each item the court placed in section 1245. General building lighting is therefore usually recovered with the building: 27.5 years if the building is residential rental property, or 39 years if it is nonresidential real property. LED retrofits, fluorescent-to-LED lamp changes, and occupancy sensors do not, by themselves, move the fixtures into a five-year class.
Metro National treated lay-in lighting in false ceilings as a structural component and allowed decorative and security lighting as personal property on the same facts. Shoney’s South allowed decorative chandeliers where separate recessed fixtures provided primary light; the IRS nonacquiesced. Those opinions show courts splitting lighting by function, not a rule that interior lighting is personal property. Whiteco’s six permanence factors are a court test for inherently permanent structures. A lay-in troffer in a grid ceiling may be removable, but Metro National still treated that lighting package as part of the building on those facts. Removability is one Whiteco question, not a statute that overrides the lighting-fixture list.
Publication 5653 matrices keep general interior lighting with the building. The residential matrix treats ceiling fans that are typically the primary light source as residential rental property. Guest-room lighting that occupies the room is building in the casino and hotel matrix. Building-mounted exterior lighting is building; pole-mounted site lighting is commonly grouped with land improvements in class 00.3 as reproduced in Publication 946 Appendix B, subject to activity-class overrides under Rev. Rul. 2003-81. Emergency exit lighting is listed with fire-protection systems in Treas. Reg. §1.263(a)-3.
AmeriSouth kept most apartment finish claims with the buildings. Boddie-Noell rejected after-the-fact lighting percentages that were not supported by contemporaneous records. A quality file photographs the occupied lighting, cites the regulation, and leaves decorative exceptions to a separate, documented set of fixtures.
Operation or maintenance of the building
The structural-component catch-all is other components relating to the operation or maintenance of a building. Occupancy lighting is the textbook example. If the lights are off, the building is not safely usable as working, housing, or sales space. That is a different question from whether a chandelier would be missed if a recessed lay-in system remained on.
How the audit guide discusses house lighting
Chapter 7 matrices place general interior lighting with the building for retail, restaurants, pharmaceuticals, casinos, auto dealerships, and residential rentals. Each matrix warns that it reflects a general fact pattern for that industry. There is no separate office-building lighting matrix. Analogy to retail or residential rows is still a facts argument.
Improvements to the electrical system
Treas. Reg. §1.263(a)-3 treats electrical systems, including lighting fixtures and connectors, as a building system for betterment, restoration, and adaptation testing. Replacing a lighting system can be a capital improvement to that system. Classification of the new fixtures is a second step. Qualified improvement property under section 168(e)(6) is an interior nonresidential improvement rule with its own exclusions; it is not a five-year lighting class.
Site lighting is a different bucket
Pole-mounted parking-lot lights are not interior building fixtures. Publication 946 class 00.3 includes land improvements such as roads and sidewalks and excludes buildings and structural components. Matrices often place site lighting with the lot. Building-mounted wall packs that light an exit door are closer to building occupancy lighting. Photograph the mounting.
Documentation
Lighting plans, fixture schedules, and photographs of typical rooms are enough for the occupancy set. If a study also claims decorative lighting, the file should show both systems and should not treat a dual-purpose fixture as decorative by labeling. Publication 5653 Chapter 4 expects original records or a documented estimate, a legal citation, and a reconciliation to basis. Estimating methods in Chapter 3 are examiner-observed approaches. Super Intelligence extraction is proposed. This page is educational information, not tax advice.
Sources
- 1
- 2
- 3IRS Publication 5653 — Cost Segregation Audit Techniques Guide (rev. 2-2025)(opens in a new tab)
Written for IRS examiners. The guide states it is not an official pronouncement of law and cannot be cited as authority. It predates the July 2025 law.
- 4Metro National Corp. v. Commissioner, T.C. Memo. 1987-38(opens in a new tab)
IRS written determination that summarizes the decision.
- 5
- 6
- 7
- 8
- 9IRS Publication 946 — How To Depreciate Property (2025)(opens in a new tab)
Appendix B reproduces the Rev. Proc. 87-56 class lives.
- 10